quote-bubble Instant Estimate shopping-cart-1 SHOP arrow-right Schedule Online phone Call Today
Heating, Plumbing & Electrical Services in Pine Island, MN
Swoop half dots

Reliable Home Services in Pine Island

Your home is one of your biggest investments, and keeping it in top condition requires dependable heating, cooling, plumbing, and electrical systems. Since 1988, K & S Heating, Air Conditioning, Plumbing, & Electrical has been the trusted choice for homeowners in Southeastern MN. With a commitment to quality and customer satisfaction, we ensure that every Pine Island home service we provide meets the highest industry standards. To see those standards in action, call us at 507-282-4328 or contact our team online for more information!

Stay Comfortable with Professional Heating & Cooling Services in Pine Island

A reliable heating and cooling system isn’t a luxury—it’s a necessity. Whether your furnace isn’t keeping up with the cold or your air conditioner struggles during the hottest days, we ensure your home stays comfortable while optimizing efficiency. K&S provides industry-leading Pine Island HVAC services, including:

  1. Furnace Repair & Replacement: A furnace that fails to provide consistent warmth can lead to uneven temperatures and high energy bills. We thoroughly assess your system, identifying inefficiencies and offering targeted furnace repairs in Pine Island or recommending high-efficiency replacements that keep your home warm without excessive costs.
  2. Furnace Maintenance: Preventative Pine Island maintenance is key to avoiding costly repairs and ensuring your system performs at its best. We inspect burners, heat exchangers, and safety controls to extend the life of your heating system.
  3. Air Conditioning Repair & Installation: A malfunctioning AC can make summer unbearable. We diagnose refrigerant leaks, compressor failures, and airflow issues to restore your system’s efficiency. When replacement is necessary, we install high-performance cooling systems that lower energy consumption and improve home comfort.
  4. Ductless Mini-Splits: Not all homes have ductwork, and for those that don’t, ductless mini-splits provide an effective heating and cooling solution. With zoned temperature control and increased efficiency, these systems help you customize comfort in different areas of your home.
  5. Heat Pumps: Heat pumps offer an energy-efficient way to heat and cool your home using the same system. These units provide year-round climate control while reducing your reliance on fossil fuels, lowering your overall utility costs.

Plumbing in Pine Island: Reliable Water Systems for Your Home

Plumbing issues can quickly disrupt your daily routine and lead to costly damage if not addressed. Whether it’s a minor leak, a slow drain, or a more serious concern like a broken pipe, our team of licensed plumbers in Pine Island respond promptly with effective solutions.

Emergency Plumbing Services

Plumbing issues don’t wait for business hours. Whether it’s a burst pipe or a backed-up drain, we provide fast emergency repairs to prevent further damage. Our team arrives quickly, assesses the situation, and provides immediate solutions to restore normalcy to your home.

Leak Detection & Repair

Small leaks often go unnoticed but can cause significant damage over time. We use specialized equipment to detect leaks behind walls, under floors, and in your home’s foundation. Early detection helps prevent mold growth, water damage, and increased water bills.

Gas Line Installation & Repair

Gas lines must be installed and maintained properly to ensure safety. Our licensed technicians handle new gas line installations and repairs, providing secure connections for stoves, water heaters, and other gas-powered appliances.

Water Filtration & Softening

Hard water can lead to mineral buildup in pipes and appliances, reducing their efficiency over time. Our water filtration and softening systems improve water quality, extend the lifespan of your plumbing, and provide cleaner, better-tasting water for your household.

RPZ Backflow Prevention Testing

Ensure your home's water remains safe and free from contamination with professional RPZ backflow prevention testing. Our certified technicians conduct thorough inspections to maintain compliance with local regulations and safeguard your drinking water.

Fixture & Pipe Installations

Whether you’re upgrading to modern fixtures or need to replace aging pipes, we offer expert installation services. Our team ensures your plumbing system meets code requirements while enhancing functionality and water efficiency.

Water Heater Services

Hot water is essential for daily comfort. If your water heater isn’t keeping up, we provide expert repairs and efficient replacement options. We also install and maintain tankless water heaters, which provide endless hot water while reducing energy waste and utility costs.

Sump Pump Installation & Repair

A functioning sump pump is crucial for preventing basement flooding and water damage. We install and maintain sump pumps to ensure they activate when needed, protecting your home from excess moisture and potential foundation issues.

K&S Electrical Services in Pine Island: Safe, Modern, and Built to Last

Outdated wiring, overloaded circuits, and faulty outlets can lead to potential hazards or inconvenient power disruptions. Our licensed electricians specialize in diagnosing electrical problems, performing necessary upgrades, and ensuring your home’s electrical system meets modern standards for safety and functionality.

  • Electrical Repairs: If you have flickering lights, malfunctioning outlets, or wiring issues, we diagnose and repair them quickly to keep your home safe and powered properly.
  • Panel Upgrades & Repairs: Outdated electrical panels can lead to overloads and power issues. We upgrade panels to meet modern power demands and prevent potential hazards.
  • Switch, Outlet & Ceiling Fan Installation: We install and update outlets, switches, and ceiling fans to improve functionality and energy efficiency.
  • Lighting & Smart Home Enhancements: Improve home security and energy efficiency with advanced lighting solutions and smart home technology.
  • EV Charger Installation: We install home EV charging stations, making it easy to keep your electric vehicle ready to go whenever you need it.

Indoor Air Quality: Creating a Healthier Pine Island Home

The air inside your home plays a crucial role in your health and comfort. Poor air quality can contribute to allergies, respiratory issues, and lingering odors. Our specialized air quality solutions help reduce airborne contaminants, maintain optimal humidity levels, and create a fresher, healthier environment for you and your family.

  • Whole-Home Humidifiers: Dry air can cause discomfort and damage wooden surfaces. Our humidifiers restore proper moisture levels for better comfort.
  • Whole-Home Dehumidifiers: Excess moisture can lead to mold and mildew. We install dehumidifiers to keep humidity under control and prevent damage.
  • UV Light Air Purifiers: Remove airborne bacteria, allergens, and contaminants with advanced UV air purification technology for a cleaner indoor environment.

Schedule Your Service in Pine Island Today

K & S Heating, Air Conditioning, Plumbing, & Electrical is your trusted partner for keeping your home’s essential systems running smoothly. Whether you need an emergency repair, a system upgrade, or routine maintenance, our team is here to help. Reach out to us today by calling 507-282-4328 to book your appointment and discover the difference of working with skilled, dependable professionals who prioritize your home's comfort and efficiency.

Recent Jobs and Reviews in Pine Island, MN

Job Locations and Reviews

Pine Island, MN - Arrived on-site and performed comprehensive air conditioning preventive maintenance tune-up. Successfully replaced malfunctioning thermostat with new Honeywell Home digital unit, which is now properly installed and displaying current temperature readings. All AC system components inspected, tested, and operating within normal parameters upon completion.
Russel C.
Russel C. Checked in
Arrived on-site and performed comprehensive air conditioning preventive maintenance tune-up. Successfully replaced malfunctioning thermostat with new Honeywell Home digital unit, which is now properly installed and displaying current temperature readings. All AC system components inspected, tested, and operating within normal parameters upon completion.
Pine Island, MN 55963
Pine Island, MN - Responded to service call for leaking water heater with visible crack in tank. Assessed existing 40-gallon power vent unit and documented current installation configuration including copper supply lines, top-mounted power vent assembly, and existing plumbing connections. Provided comprehensive estimate for replacement with comparable 40-gallon power vent water heater.
Richard B.
Richard B. Checked in
Responded to service call for leaking water heater with visible crack in tank. Assessed existing 40-gallon power vent unit and documented current installation configuration including copper supply lines, top-mounted power vent assembly, and existing plumbing connections. Provided comprehensive estimate for replacement with comparable 40-gallon power vent water heater.
Pine Island, MN 55963
Completed comprehensive plumbing inspection of main waterline, sediment filter, and water softener system. Identified three-quarter inch shut-off valve before meter with broken handle requiring replacement, sediment filter before water softener needing routine maintenance every six months to one year based on condition, and aging Kenmore Ultra Soft 180 water softener exceeding 15-year resin lifespan requiring replacement. Recommended replacing flexible water supply lines with traditional hard copper piping during softener replacement for improved durability and code compliance, and provided detailed estimate for all recommended repairs and upgrades.
Completed comprehensive plumbing inspection of main waterline, sediment filter, and water softener system. Identified three-quarter inch shut-off valve before meter with broken handle requiring replacement, sediment filter before water softener needing routine maintenance every six months to one year based on condition, and aging Kenmore Ultra Soft 180 water softener exceeding 15-year resin lifespan requiring replacement. Recommended replacing flexible water supply lines with traditional hard copper piping during softener replacement for improved durability and code compliance, and provided detailed estimate for all recommended repairs and upgrades.
Richard B.
Richard B. Checked in
Completed comprehensive plumbing inspection of main waterline, sediment filter, and water softener system. Identified three-quarter inch shut-off valve before meter with broken handle requiring replacement, sediment filter before water softener needing routine maintenance every six months to one year based on condition, and aging Kenmore Ultra Soft 180 water softener exceeding 15-year resin lifespan requiring replacement. Recommended replacing flexible water supply lines with traditional hard copper piping during softener replacement for improved durability and code compliance, and provided detailed estimate for all recommended repairs and upgrades.
Pine Island, MN 55963
Responded to service call for electrical panel wiring repair identified during home inspection. Upon arrival, accessed and inspected main electrical panel box containing dual rows of circuit breakers and main disconnect assembly. Corrected improper wire connection in panel as flagged by inspection report. Verified all circuit breaker connections, bus bar integrity, and grounding wire terminations met current electrical code requirements. Documented panel condition with photographs showing before and after states of repair work performed.
Responded to service call for electrical panel wiring repair identified during home inspection. Upon arrival, accessed and inspected main electrical panel box containing dual rows of circuit breakers and main disconnect assembly. Corrected improper wire connection in panel as flagged by inspection report. Verified all circuit breaker connections, bus bar integrity, and grounding wire terminations met current electrical code requirements. Documented panel condition with photographs showing before and after states of repair work performed.
Dawson S.
Dawson S. Checked in
Responded to service call for electrical panel wiring repair identified during home inspection. Upon arrival, accessed and inspected main electrical panel box containing dual rows of circuit breakers and main disconnect assembly. Corrected improper wire connection in panel as flagged by inspection report. Verified all circuit breaker connections, bus bar integrity, and grounding wire terminations met current electrical code requirements. Documented panel condition with photographs showing before and after states of repair work performed.
Pine Island, MN 55963
Pine Island, MN - Responded to bathtub and shower faucet with steady drip occurring while both control knobs were in the off position. Diagnosed failed stem assembly as the source of the leak. Presented customer with two rebuild options and one complete replacement option for repair.
Andrew N.
Andrew N. Checked in
Responded to bathtub and shower faucet with steady drip occurring while both control knobs were in the off position. Diagnosed failed stem assembly as the source of the leak. Presented customer with two rebuild options and one complete replacement option for repair.
Pine Island, MN 55963
Pine Island, MN - Responded to service call for A.O. Smith tanked water heater that was not lighting. Upon inspection, determined that the high-limit temperature sensor had tripped, indicating a safety shutdown. Reset the gas control valve and high-limit sensor, restoring proper operation. Water heater ignited successfully and returned to normal heating function following the repair.
Andrew N.
Andrew N. Checked in
Responded to service call for A.O. Smith tanked water heater that was not lighting. Upon inspection, determined that the high-limit temperature sensor had tripped, indicating a safety shutdown. Reset the gas control valve and high-limit sensor, restoring proper operation. Water heater ignited successfully and returned to normal heating function following the repair.
Pine Island, MN 55963
Arrived on-site within scheduled 8-12 window and conducted assessment of existing copper plumbing infrastructure for installation of customer-supplied water softener unit. Evaluated current pipe configuration, including vertical runs and U-bend sections with soldered joints, to determine optimal integration point for the softening system. Provided detailed estimate for complete installation of the customer-supplied water treatment equipment, including necessary connections, bypass valve configuration, drain line routing, and electrical requirements for the control valve system observed in the existing plumbing setup.
Arrived on-site within scheduled 8-12 window and conducted assessment of existing copper plumbing infrastructure for installation of customer-supplied water softener unit. Evaluated current pipe configuration, including vertical runs and U-bend sections with soldered joints, to determine optimal integration point for the softening system. Provided detailed estimate for complete installation of the customer-supplied water treatment equipment, including necessary connections, bypass valve configuration, drain line routing, and electrical requirements for the control valve system observed in the existing plumbing setup.
Andrew N.
Andrew N. Checked in
Arrived on-site within scheduled 8-12 window and conducted assessment of existing copper plumbing infrastructure for installation of customer-supplied water softener unit. Evaluated current pipe configuration, including vertical runs and U-bend sections with soldered joints, to determine optimal integration point for the softening system. Provided detailed estimate for complete installation of the customer-supplied water treatment equipment, including necessary connections, bypass valve configuration, drain line routing, and electrical requirements for the control valve system observed in the existing plumbing setup.
Pine Island, MN 55963
# Warranty Service Completion Summary

Completed warranty replacement of defective pressure switch on HVAC system. Coordinated afternoon arrival time per customer's scheduling preference and provided advance notification prior to arrival. Successfully removed failed pressure switch and installed manufacturer-supplied warranty replacement part, ensuring proper electrical connections and secure mounting to blower assembly. Verified all wire terminations, tested system operation, and confirmed proper pressure switch functionality. Unit restored to full operational status with all safety controls operating within specifications.
# Warranty Service Completion Summary

Completed warranty replacement of defective pressure switch on HVAC system. Coordinated afternoon arrival time per customer's scheduling preference and provided advance notification prior to arrival. Successfully removed failed pressure switch and installed manufacturer-supplied warranty replacement part, ensuring proper electrical connections and secure mounting to blower assembly. Verified all wire terminations, tested system operation, and confirmed proper pressure switch functionality. Unit restored to full operational status with all safety controls operating within specifications.
Braden P.
Braden P. Checked in
# Warranty Service Completion Summary Completed warranty replacement of defective pressure switch on HVAC system. Coordinated afternoon arrival time per customer's scheduling preference and provided advance notification prior to arrival. Successfully removed failed pressure switch and installed manufacturer-supplied warranty replacement part, ensuring proper electrical connections and secure mounting to blower assembly. Verified all wire terminations, tested system operation, and confirmed proper pressure switch functionality. Unit restored to full operational status with all safety controls operating within specifications.
Pine Island, MN 55963
Pine Island, MN - Responded to no-heat call for 10+ year old Lennox furnace. Diagnosed dirty flame sensor causing heat failure. Cleaned flame sensor and performed complete system tune-up, restoring normal heating operation. Unit is functioning properly with all safety systems verified.
Russel C.
Russel C. Checked in
Responded to no-heat call for 10+ year old Lennox furnace. Diagnosed dirty flame sensor causing heat failure. Cleaned flame sensor and performed complete system tune-up, restoring normal heating operation. Unit is functioning properly with all safety systems verified.
Pine Island, MN 55963
Conducted electrical inspection of residential property. Verified functionality of GFCI outlets and examined digital thermostat system set at 78 degrees. All inspected components appear properly installed and in normal working condition.
Conducted electrical inspection of residential property. Verified functionality of GFCI outlets and examined digital thermostat system set at 78 degrees. All inspected components appear properly installed and in normal working condition.
Dawson S.
Dawson S. Checked in
Conducted electrical inspection of residential property. Verified functionality of GFCI outlets and examined digital thermostat system set at 78 degrees. All inspected components appear properly installed and in normal working condition.
Pine Island, MN 55963
Pine Island, MN - Responded to no heat callback with system showing red light error. Diagnosed rollout switch issue, performed reset, and verified proper intake/exhaust operation to restore heat functionality. System now operating normally.
Cael D.
Cael D. Checked in
Responded to no heat callback with system showing red light error. Diagnosed rollout switch issue, performed reset, and verified proper intake/exhaust operation to restore heat functionality. System now operating normally.
Pine Island, MN 55963
Diagnosed no heat issue where thermostat couldn't exceed 62°F and was delivering cold air. Inspection revealed a faulty dual pressure switch which was replaced to restore proper system operation. Also noted significant dust accumulation on air filter requiring immediate attention to prevent airflow restriction and potential system damage.
Diagnosed no heat issue where thermostat couldn't exceed 62°F and was delivering cold air. Inspection revealed a faulty dual pressure switch which was replaced to restore proper system operation. Also noted significant dust accumulation on air filter requiring immediate attention to prevent airflow restriction and potential system damage.
Braden P.
Braden P. Checked in
Diagnosed no heat issue where thermostat couldn't exceed 62°F and was delivering cold air. Inspection revealed a faulty dual pressure switch which was replaced to restore proper system operation. Also noted significant dust accumulation on air filter requiring immediate attention to prevent airflow restriction and potential system damage.
Pine Island, MN 55963
Arrived during scheduled window for water softener estimate. Assessed existing water treatment system consisting of a dual-tank setup (blue cylindrical softener unit and taller filtration/conditioner tank) with accompanying piping and connections. Provided comprehensive estimate for recommended two-piece water treatment solution based on evaluation of current equipment and household needs.
Arrived during scheduled window for water softener estimate. Assessed existing water treatment system consisting of a dual-tank setup (blue cylindrical softener unit and taller filtration/conditioner tank) with accompanying piping and connections. Provided comprehensive estimate for recommended two-piece water treatment solution based on evaluation of current equipment and household needs.
Richard B.
Richard B. Checked in
Arrived during scheduled window for water softener estimate. Assessed existing water treatment system consisting of a dual-tank setup (blue cylindrical softener unit and taller filtration/conditioner tank) with accompanying piping and connections. Provided comprehensive estimate for recommended two-piece water treatment solution based on evaluation of current equipment and household needs.
Pine Island, MN 55963
Successfully installed collector box on HVAC system during scheduled appointment. Opened unit to access internal components, connected appropriate wiring harnesses and PVC drainage pipes, then thoroughly tested system operation to confirm proper functionality.
Successfully installed collector box on HVAC system during scheduled appointment. Opened unit to access internal components, connected appropriate wiring harnesses and PVC drainage pipes, then thoroughly tested system operation to confirm proper functionality.
Cael D.
Cael D. Checked in
Successfully installed collector box on HVAC system during scheduled appointment. Opened unit to access internal components, connected appropriate wiring harnesses and PVC drainage pipes, then thoroughly tested system operation to confirm proper functionality.
Pine Island, MN 55963
Pine Island, MN - Diagnosed G61 furnace failure with no heat production. Inspection revealed faulty hot surface ignitor (HSI) preventing system ignition. Replaced defective HSI component, restoring proper furnace operation and heat production.
Russel C.
Russel C. Checked in
Diagnosed G61 furnace failure with no heat production. Inspection revealed faulty hot surface ignitor (HSI) preventing system ignition. Replaced defective HSI component, restoring proper furnace operation and heat production.
Pine Island, MN 55963
Performed scheduled preventative maintenance on furnace per agreement. Conducted combustion analysis with readings of CO2 at 8.3% and excess air at 42.6%. Inspected internal components and wiring connections, verifying proper operation of system.
Performed scheduled preventative maintenance on furnace per agreement. Conducted combustion analysis with readings of CO2 at 8.3% and excess air at 42.6%. Inspected internal components and wiring connections, verifying proper operation of system.
Russel C.
Russel C. Checked in
Performed scheduled preventative maintenance on furnace per agreement. Conducted combustion analysis with readings of CO2 at 8.3% and excess air at 42.6%. Inspected internal components and wiring connections, verifying proper operation of system.
Pine Island, MN 55963
Pine Island, MN - Completed scheduled preventative maintenance service on Amana furnace system per agreement. Inspected all components including heat exchanger, ventilation system, and copper refrigerant lines. System is properly installed with appropriate PVC venting and appears to be functioning within normal parameters.
Cael D.
Cael D. Checked in
Completed scheduled preventative maintenance service on Amana furnace system per agreement. Inspected all components including heat exchanger, ventilation system, and copper refrigerant lines. System is properly installed with appropriate PVC venting and appears to be functioning within normal parameters.
Pine Island, MN 55963
Completed scheduled maintenance agreement service on residential furnace system. Performed comprehensive tune-up including inspection of internal components, electrical connections, and ventilation system. Diagnostic testing confirmed proper operation of all systems with no issues identified.
Completed scheduled maintenance agreement service on residential furnace system. Performed comprehensive tune-up including inspection of internal components, electrical connections, and ventilation system. Diagnostic testing confirmed proper operation of all systems with no issues identified.
Yahya A.
Yahya A. Checked in
Completed scheduled maintenance agreement service on residential furnace system. Performed comprehensive tune-up including inspection of internal components, electrical connections, and ventilation system. Diagnostic testing confirmed proper operation of all systems with no issues identified.
Pine Island, MN 55963
Pine Island, MN - Responded to no heat call and diagnosed short cycling due to a restrictive filter. Performed complete system maintenance including replacement of transformer for humidifier and UV light, restoring proper system operation.
Cael D.
Cael D. Checked in
Responded to no heat call and diagnosed short cycling due to a restrictive filter. Performed complete system maintenance including replacement of transformer for humidifier and UV light, restoring proper system operation.
Pine Island, MN 55963
Pine Island, MN - Responded to service call for HVAC system malfunction. Diagnosed failed blower motor and installed new capacitor as per previously sold repair. System functionality restored and verified proper operation after component replacement.
Cael D.
Cael D. Checked in
Responded to service call for HVAC system malfunction. Diagnosed failed blower motor and installed new capacitor as per previously sold repair. System functionality restored and verified proper operation after component replacement.
Pine Island, MN 55963
Schedule Service Online
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 507-282-4328 .

By pressing Submit I agree to receive phone, email, or text messages from K&S Heating, Air Conditioning, Plumbing & Electrical to the provided mobile number and also agree to the K&S Heating, Air Conditioning, Plumbing & Electrical terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next