quote-bubble Instant Estimate shopping-cart-1 SHOP arrow-right Schedule Online phone Call Today
Heating, Plumbing & Electrical Services in Austin, MN
Swoop half dots

Peace of Mind with Home Services in Austin, MN

Your home is more than just a place to live—it's where life happens. At K&S Heating, Air Conditioning, Plumbing, & Electrical, we believe in providing services that go beyond just fixing problems. Our team is here to make sure you have peace of mind when it comes to your heating, cooling, plumbing, or electrical systems. With decades of experience and a commitment to quality home comfort services in Austin, call the K&S team today at 507-282-4328 or contact us online for more information!

Reliable Austin Plumbing Services When you Need Them Most

A plumbing issue can quickly turn into a major disruption, whether it's a dripping faucet keeping you up at night or a clogged drain slowing down your routine. Our team is here to take the stress out of plumbing problems by providing fast, reliable plumbing services in Austin that get your home back to normal—without the headache.

  • Fast & Effective Plumbing Repairs in Austin: Leaky faucet? Slow drain? Unexpected water pressure problems? We diagnose and fix issues quickly, so you can get back to what matters.
  • Emergency Plumbing Services: When a pipe bursts or a water heater fails, waiting isn't an option. We provide urgent plumbing repairs to minimize damage and restore your home's function.
  • Water Heater Installation & Repair: Reliable hot water is essential. Whether you need a repair or a new energy-efficient system, we ensure you always have hot water when you need it.
  • Austin Tankless Water Heater Solutions: Say goodbye to running out of hot water—tankless systems provide an endless supply while saving energy.
  • Leak Detection & Prevention: Water damage can be costly and stressful. We use specially-designed leak detection tools to identify and fix hidden plumbing issues before they become major problems.
  • Sump Pump Installation & Repair in Austin: Keep your basement dry and protected from water damage with a reliable sump pump system.
  • Water Filtration & Softening: Enjoy cleaner, healthier water while protecting your plumbing from mineral buildup with filtration and softening solutions.
  • Plumbing Installations Done Right: From kitchen upgrades to bathroom remodels, we install new sinks, toilets, showers, and more with expert care.
  • Gas Line Services: Safety is our top priority. Whether you need a new gas line for an appliance or a repair, we handle it with precision and care.
  • RPZ Backflow Prevention Testing: Ensure your home's water supply remains safe and free from contamination with professional RPZ backflow testing and certification in Austin.

Dependable Austin Heating & Cooling Services

Your home should be a place of comfort, no matter how hot or cold it gets outside. The K&S team is here to make sure your heating and cooling work reliably, so you can focus on enjoying your home instead of dealing with temperature swings. When you use our heating and cooling services in Austin, you get access to:

  • Furnace Repair & Installation: A reliable furnace is a must in Minnesota winters. If yours isn't working properly, we'll repair it or install a new high-efficiency model.
  • Furnace Maintenance: Regular furnace maintenance in Austin keeps your system efficient, prevents breakdowns, and extends its lifespan.
  • Air Conditioning Services in Austin: We repair, install, and maintain air conditioning systems to keep your home cool and comfortable.
  • Ductless Mini-Splits: Great for homes without ductwork, these systems provide targeted heating and cooling where you need it.
  • Heat Pumps: A smart, energy-efficient way to maintain year-round comfort with a single system.

Dependable Electrical Services in Austin for a Safe & Efficient Home

Electricity powers everything in your home, from your new tech gadgets to your kitchen appliances. You shouldn't have to think twice about whether your system is up to the tasks. Our expert electricians ensure everything is up to code and working as it should. Power your whole home with these Austin electrical services:

Electrical Panel Upgrades

If your electrical panel is outdated, frequently trips, or struggles to keep up with modern electrical demands, it's time for an upgrade. We replace outdated panels in Austin with newer, safer models that provide better energy efficiency and reduce the risk of electrical hazards.

Austin Electrical Repairs

From flickering lights and tripped breakers to faulty wiring and power surges, electrical issues can be more than just an inconvenience—they can be a safety risk. We diagnose and repair problems quickly to restore power and prevent potential hazards.

Indoor & Outdoor Lighting

Lighting isn't just about visibility—it sets the mood, enhances security, and increases energy efficiency. We install everything from elegant interior lighting to motion-activated security lights that add safety and curb appeal to your home.

Outlet & Switch Installations

If your home lacks enough outlets or you need modern upgrades like USB-equipped outlets and smart switches, we handle installations safely and professionally. We also replace old, worn-out outlets that could pose fire risks.

Smart Home Solutions

Upgrade your home with technology that simplifies your life. We install automated lighting, smart thermostats, video doorbells, and security systems that allow you to control your home from anywhere.

Ceiling Fan Installation

A properly installed ceiling fan helps regulate temperature, improve air circulation, and lower energy costs. We ensure secure, well-balanced installations that fit seamlessly into your home's design.

EV Charger Installation

Owning an electric vehicle should be convenient. We install Level 1 and Level 2 EV chargers, giving you a fast, reliable way to power your car at home while ensuring your electrical system can handle the added demand.

Breathe Easier with Whole-Home Air Quality Services in Austin

You spend most of your time at home, so the air you breathe should be fresh and healthy. Dust, allergens, and humidity levels can impact your comfort, energy levels, and even your health. Our whole-home air quality solutions help reduce allergens, manage moisture, and eliminate airborne contaminants, so you can breathe easier every day.

  • Whole Home Humidifiers: Dry indoor air can cause discomfort, aggravate allergies, and even damage wood furniture. Our whole-home humidifiers add the right amount of moisture to the air, improving comfort and protecting your home.
  • Whole Home Dehumidifiers: Too much moisture in the air can lead to mold, mildew, and musty odors. Our whole-home dehumidifiers maintain the perfect humidity balance to reduce allergens and keep your home feeling fresh.
  • UV Light Air Purification: Invisible threats like bacteria, allergens, and viruses can linger in the air. Our UV light purification systems eliminate harmful airborne contaminants, creating a healthier environment for your family.

Take Back Your Peace of Mind Today!

Your home should be a place of comfort, not stress. At K&S Heating, Air, Plumbing & Electrical, we take pride in delivering reliable service that keeps your home running smoothly. Whether it's a routine maintenance check or an unexpected repair, you can trust our experienced team to provide solutions that last. Give us a call today at 507-282-4328 and experience the peace of mind that comes with having experts on your side.

Recent Jobs and Reviews in Austin, MN

Austin, MN at a glance

K&S Heating, Air Conditioning, Plumbing & Electrical has completed 20 jobs in Austin, MN between May 2026 and October 2026.

The most recent job was on October 5, 2026.

K&S Heating, Air Conditioning, Plumbing & Electrical has completed 111 jobs in Austin, MN in the last 12 months.

Job Locations and Reviews

Responded to no heat call and arrived on site to diagnose furnace issue. Upon inspection, determined heating system was operational with no mechanical or electrical faults present. Conducted customer education on proper thermostat operation and programming. Performed visual inspection of ductwork using borescope camera to verify system integrity. System restored to normal heating operation after thermostat instruction provided.
Responded to no heat call and arrived on site to diagnose furnace issue. Upon inspection, determined heating system was operational with no mechanical or electrical faults present. Conducted customer education on proper thermostat operation and programming. Performed visual inspection of ductwork using borescope camera to verify system integrity. System restored to normal heating operation after thermostat instruction provided.
Braden P.
Braden P. Checked in
Responded to no heat call and arrived on site to diagnose furnace issue. Upon inspection, determined heating system was operational with no mechanical or electrical faults present. Conducted customer education on proper thermostat operation and programming. Performed visual inspection of ductwork using borescope camera to verify system integrity. System restored to normal heating operation after thermostat instruction provided.
Austin, MN 55912
Austin, MN - Responded to no hot water call and performed on-site assessment of 40-gallon power vent LP water heater. Upon inspection, identified active leak originating from the tank itself, rendering the unit beyond repair. Documented existing installation including power vent configuration and LP gas connection in basement utility area alongside water treatment equipment. Provided comprehensive estimate for replacement with new 40-gallon power vent LP water heater to restore hot water service.
Richard B.
Richard B. Checked in
Responded to no hot water call and performed on-site assessment of 40-gallon power vent LP water heater. Upon inspection, identified active leak originating from the tank itself, rendering the unit beyond repair. Documented existing installation including power vent configuration and LP gas connection in basement utility area alongside water treatment equipment. Provided comprehensive estimate for replacement with new 40-gallon power vent LP water heater to restore hot water service.
Austin, MN 55912
Responded to upstairs bathroom vanity sink draining into basement bathroom. Created wall access to inspect drainage system and discovered 1-1/2" galvanized lavatory drain had separated at the tee fitting inside the wall cavity. Upon further investigation, found extensive buildup throughout the drain line preventing proper drainage. Documented conditions showing corroded galvanized piping, deteriorated fittings, and significant moisture damage to surrounding wall framing. Advised that drain line requires hydro jetting service to remove blockages and restore proper flow before reassembly can be completed.
Responded to upstairs bathroom vanity sink draining into basement bathroom. Created wall access to inspect drainage system and discovered 1-1/2" galvanized lavatory drain had separated at the tee fitting inside the wall cavity. Upon further investigation, found extensive buildup throughout the drain line preventing proper drainage. Documented conditions showing corroded galvanized piping, deteriorated fittings, and significant moisture damage to surrounding wall framing. Advised that drain line requires hydro jetting service to remove blockages and restore proper flow before reassembly can be completed.
Andrew N.
Andrew N. Checked in
Responded to upstairs bathroom vanity sink draining into basement bathroom. Created wall access to inspect drainage system and discovered 1-1/2" galvanized lavatory drain had separated at the tee fitting inside the wall cavity. Upon further investigation, found extensive buildup throughout the drain line preventing proper drainage. Documented conditions showing corroded galvanized piping, deteriorated fittings, and significant moisture damage to surrounding wall framing. Advised that drain line requires hydro jetting service to remove blockages and restore proper flow before reassembly can be completed.
Austin, MN 55912
Responded to service call for water heater not staying lit. Upon arrival, performed diagnostic inspection and identified obstruction of combustible air intakes caused by storage items placed in close proximity to the unit. Cleared adequate clearance around the water heater to ensure proper ventilation and combustion air supply. Successfully relit pilot light and verified burner ignition and operation. Tested unit through complete heating cycle with all systems functioning properly. Educated property occupant on required clearances around gas-fired appliances for safe operation and code compliance.
Responded to service call for water heater not staying lit. Upon arrival, performed diagnostic inspection and identified obstruction of combustible air intakes caused by storage items placed in close proximity to the unit. Cleared adequate clearance around the water heater to ensure proper ventilation and combustion air supply. Successfully relit pilot light and verified burner ignition and operation. Tested unit through complete heating cycle with all systems functioning properly. Educated property occupant on required clearances around gas-fired appliances for safe operation and code compliance.
Andrew N.
Andrew N. Checked in
Responded to service call for water heater not staying lit. Upon arrival, performed diagnostic inspection and identified obstruction of combustible air intakes caused by storage items placed in close proximity to the unit. Cleared adequate clearance around the water heater to ensure proper ventilation and combustion air supply. Successfully relit pilot light and verified burner ignition and operation. Tested unit through complete heating cycle with all systems functioning properly. Educated property occupant on required clearances around gas-fired appliances for safe operation and code compliance.
Austin, MN 55912
Austin, MN - Responded to service call for leaking garbage disposal and completed on-site replacement. Existing unit was hardwired to electrical supply, while replacement unit came equipped with standard plug connection requiring outlet installation. Successfully installed new garbage disposal unit with appropriate electrical modifications to accommodate plug-style connection.
Andrew N.
Andrew N. Checked in
Responded to service call for leaking garbage disposal and completed on-site replacement. Existing unit was hardwired to electrical supply, while replacement unit came equipped with standard plug connection requiring outlet installation. Successfully installed new garbage disposal unit with appropriate electrical modifications to accommodate plug-style connection.
Austin, MN 55912
Austin, MN - Responded to a leaking toilet shut-off valve and improper toilet seal. Replaced the defective shut-off valve with a new chrome supply valve and installed a new wax ring. Reset the toilet to ensure proper seal and verified all connections were leak-free upon completion.
Richard B.
Richard B. Checked in
Responded to a leaking toilet shut-off valve and improper toilet seal. Replaced the defective shut-off valve with a new chrome supply valve and installed a new wax ring. Reset the toilet to ensure proper seal and verified all connections were leak-free upon completion.
Austin, MN 55912
Responded to service call for leaking cast iron drain line. Upon inspection, discovered a quarter-sized hole in the 4" cast iron drain pipe near floor level, with an additional 6-8 inches of severely corroded pipe extending toward the slab foundation. The corroded section exhibited significant deterioration with rust and structural compromise requiring replacement. Documented the damage with photographs showing the extent of corrosion at the pipe base and water damage to the surrounding floor area. Due to the location of the damaged section entering the slab, concrete floor demolition will be necessary to access and replace the affected drain line. Forwarded all inspection findings and photographic documentation to schedule follow-up appointment for the required excavation and pipe replacement work.
Responded to service call for leaking cast iron drain line. Upon inspection, discovered a quarter-sized hole in the 4" cast iron drain pipe near floor level, with an additional 6-8 inches of severely corroded pipe extending toward the slab foundation. The corroded section exhibited significant deterioration with rust and structural compromise requiring replacement. Documented the damage with photographs showing the extent of corrosion at the pipe base and water damage to the surrounding floor area. Due to the location of the damaged section entering the slab, concrete floor demolition will be necessary to access and replace the affected drain line. Forwarded all inspection findings and photographic documentation to schedule follow-up appointment for the required excavation and pipe replacement work.
Andrew N.
Andrew N. Checked in
Responded to service call for leaking cast iron drain line. Upon inspection, discovered a quarter-sized hole in the 4" cast iron drain pipe near floor level, with an additional 6-8 inches of severely corroded pipe extending toward the slab foundation. The corroded section exhibited significant deterioration with rust and structural compromise requiring replacement. Documented the damage with photographs showing the extent of corrosion at the pipe base and water damage to the surrounding floor area. Due to the location of the damaged section entering the slab, concrete floor demolition will be necessary to access and replace the affected drain line. Forwarded all inspection findings and photographic documentation to schedule follow-up appointment for the required excavation and pipe replacement work.
Austin, MN 55912
Responded to a tripped breaker issue in the utility room basement caused by a sump pump. Upon arrival, diagnosed that the sump pump was overloading the circuit and causing the breaker to trip. Evaluated the electrical system, tested the circuit, and provided the customer with multiple solution options to prevent future tripping and ensure safe operation of the sump pump system.
Responded to a tripped breaker issue in the utility room basement caused by a sump pump. Upon arrival, diagnosed that the sump pump was overloading the circuit and causing the breaker to trip. Evaluated the electrical system, tested the circuit, and provided the customer with multiple solution options to prevent future tripping and ensure safe operation of the sump pump system.
Dawson S.
Dawson S. Checked in
Responded to a tripped breaker issue in the utility room basement caused by a sump pump. Upon arrival, diagnosed that the sump pump was overloading the circuit and causing the breaker to trip. Evaluated the electrical system, tested the circuit, and provided the customer with multiple solution options to prevent future tripping and ensure safe operation of the sump pump system.
Austin, MN 55912
Responded to service call for non-functional electrical outlet being used with portable air conditioning unit. Upon inspection, determined that the existing outlet circuit was insufficient to handle the electrical load requirements of the AC unit. Installed new dedicated circuit with appropriate amperage capacity and replaced the outlet to safely accommodate the portable air conditioner, ensuring compliance with electrical code requirements for high-draw appliances.
Responded to service call for non-functional electrical outlet being used with portable air conditioning unit. Upon inspection, determined that the existing outlet circuit was insufficient to handle the electrical load requirements of the AC unit. Installed new dedicated circuit with appropriate amperage capacity and replaced the outlet to safely accommodate the portable air conditioner, ensuring compliance with electrical code requirements for high-draw appliances.
Dawson S.
Dawson S. Checked in
Responded to service call for non-functional electrical outlet being used with portable air conditioning unit. Upon inspection, determined that the existing outlet circuit was insufficient to handle the electrical load requirements of the AC unit. Installed new dedicated circuit with appropriate amperage capacity and replaced the outlet to safely accommodate the portable air conditioner, ensuring compliance with electrical code requirements for high-draw appliances.
Austin, MN 55912
Austin, MN - Responded to no cooling complaint on aging residential air conditioning system. Upon arrival, found outdoor condenser unit buzzing but fan blades not spinning. Discovered tripped breaker at electrical panel and reset. Diagnosed failed dual run capacitor preventing condenser fan motor operation. Replaced defective capacitor with proper OEM equivalent. Verified system startup, confirmed proper amperage draw on compressor and fan motor, and restored normal cooling operation.
Braden P.
Braden P. Checked in
Responded to no cooling complaint on aging residential air conditioning system. Upon arrival, found outdoor condenser unit buzzing but fan blades not spinning. Discovered tripped breaker at electrical panel and reset. Diagnosed failed dual run capacitor preventing condenser fan motor operation. Replaced defective capacitor with proper OEM equivalent. Verified system startup, confirmed proper amperage draw on compressor and fan motor, and restored normal cooling operation.
Austin, MN 55912
Responded to service call for upstairs toilet that was not flushing properly. Upon inspection, determined the issue was a clogged main line rather than an isolated toilet blockage. Accessed plumbing infrastructure through existing wall panel to assess main drain line condition and confirmed diagnosis. Provided referral for main line clearing service due to scope of work required.
Responded to service call for upstairs toilet that was not flushing properly. Upon inspection, determined the issue was a clogged main line rather than an isolated toilet blockage. Accessed plumbing infrastructure through existing wall panel to assess main drain line condition and confirmed diagnosis. Provided referral for main line clearing service due to scope of work required.
Dan A.
Dan A. Checked in
Responded to service call for upstairs toilet that was not flushing properly. Upon inspection, determined the issue was a clogged main line rather than an isolated toilet blockage. Accessed plumbing infrastructure through existing wall panel to assess main drain line condition and confirmed diagnosis. Provided referral for main line clearing service due to scope of work required.
Austin, MN 55912
Responded to service call for toilet running continuously due to faulty flush handle mechanism. Upon arrival, confirmed handle was sticking and preventing proper valve closure. Removed tank lid, inspected internal components, and replaced defective flush handle assembly. Tested operation multiple times to ensure proper function and complete shutoff. Tank interior showed mineral deposits and staining but all mechanical components now operating correctly.
Responded to service call for toilet running continuously due to faulty flush handle mechanism. Upon arrival, confirmed handle was sticking and preventing proper valve closure. Removed tank lid, inspected internal components, and replaced defective flush handle assembly. Tested operation multiple times to ensure proper function and complete shutoff. Tank interior showed mineral deposits and staining but all mechanical components now operating correctly.
Dustin S.
Dustin S. Checked in
Responded to service call for toilet running continuously due to faulty flush handle mechanism. Upon arrival, confirmed handle was sticking and preventing proper valve closure. Removed tank lid, inspected internal components, and replaced defective flush handle assembly. Tested operation multiple times to ensure proper function and complete shutoff. Tank interior showed mineral deposits and staining but all mechanical components now operating correctly.
Austin, MN 55912
Austin, MN - Responded to no cooling call on residential system. Upon arrival, found indoor blower fan running continuously. Diagnosed failed limit switch causing fan to operate without cycling. Replaced defective limit switch and restored normal system operation with proper fan cycling.
Chris E.
Chris E. Checked in
Responded to no cooling call on residential system. Upon arrival, found indoor blower fan running continuously. Diagnosed failed limit switch causing fan to operate without cycling. Replaced defective limit switch and restored normal system operation with proper fan cycling.
Austin, MN 55912
Austin, MN - Responded to no cooling call on residential air conditioning system. Upon arrival, diagnosed failed condenser fan motor preventing outdoor unit operation. Replaced defective condenser fan motor and verified proper amperage draw and system operation before departure.
Braden P.
Braden P. Checked in
Responded to no cooling call on residential air conditioning system. Upon arrival, diagnosed failed condenser fan motor preventing outdoor unit operation. Replaced defective condenser fan motor and verified proper amperage draw and system operation before departure.
Austin, MN 55912
Responded to no-cooling complaint on Carrier Puron system. Diagnosed low refrigerant charge as cause of insufficient cooling capacity. Added refrigerant to manufacturer specifications and injected UV dye pack into system to facilitate future leak detection if necessary.
Responded to no-cooling complaint on Carrier Puron system. Diagnosed low refrigerant charge as cause of insufficient cooling capacity. Added refrigerant to manufacturer specifications and injected UV dye pack into system to facilitate future leak detection if necessary.
Braden P.
Braden P. Checked in
Responded to no-cooling complaint on Carrier Puron system. Diagnosed low refrigerant charge as cause of insufficient cooling capacity. Added refrigerant to manufacturer specifications and injected UV dye pack into system to facilitate future leak detection if necessary.
Austin, MN 55912
Responded to no cooling complaint on recently installed system. Unit had not received initial startup service following installation from previous fall. Performed complete startup procedure on unit 2, including system checks and operational verification. System now cooling properly.
Responded to no cooling complaint on recently installed system. Unit had not received initial startup service following installation from previous fall. Performed complete startup procedure on unit 2, including system checks and operational verification. System now cooling properly.
Braden P.
Braden P. Checked in
Responded to no cooling complaint on recently installed system. Unit had not received initial startup service following installation from previous fall. Performed complete startup procedure on unit 2, including system checks and operational verification. System now cooling properly.
Austin, MN 55912
Responded to no cooling complaint on aging York AC system. Upon arrival, found evidence of previous ice buildup on evaporator coil and confirmed unit was low on R-22 refrigerant. Performed system diagnostics and pressure testing to verify refrigerant loss. Given the system's age (10+ years), deteriorated condition of both the air handler and outdoor condensing unit, obsolete R-22 refrigerant requirements, and overall wear evident throughout the equipment, recommended full system replacement rather than repair. Discussed replacement options with property owner due to diminishing availability and increasing cost of R-22 refrigerant, as well as the likelihood of additional component failures in the near future.
Responded to no cooling complaint on aging York AC system. Upon arrival, found evidence of previous ice buildup on evaporator coil and confirmed unit was low on R-22 refrigerant. Performed system diagnostics and pressure testing to verify refrigerant loss. Given the system's age (10+ years), deteriorated condition of both the air handler and outdoor condensing unit, obsolete R-22 refrigerant requirements, and overall wear evident throughout the equipment, recommended full system replacement rather than repair. Discussed replacement options with property owner due to diminishing availability and increasing cost of R-22 refrigerant, as well as the likelihood of additional component failures in the near future.
Chris E.
Chris E. Checked in
Responded to no cooling complaint on aging York AC system. Upon arrival, found evidence of previous ice buildup on evaporator coil and confirmed unit was low on R-22 refrigerant. Performed system diagnostics and pressure testing to verify refrigerant loss. Given the system's age (10+ years), deteriorated condition of both the air handler and outdoor condensing unit, obsolete R-22 refrigerant requirements, and overall wear evident throughout the equipment, recommended full system replacement rather than repair. Discussed replacement options with property owner due to diminishing availability and increasing cost of R-22 refrigerant, as well as the likelihood of additional component failures in the near future.
Austin, MN 55912
Responded to no power call for non-functioning lights. Upon inspection, identified tripped circuit breaker in electrical panel. Reset breaker to restore power and verified proper operation of lighting system.
Responded to no power call for non-functioning lights. Upon inspection, identified tripped circuit breaker in electrical panel. Reset breaker to restore power and verified proper operation of lighting system.
Dawson S.
Dawson S. Checked in
Responded to no power call for non-functioning lights. Upon inspection, identified tripped circuit breaker in electrical panel. Reset breaker to restore power and verified proper operation of lighting system.
Austin, MN 55912
Completed installation of water treatment system in basement utility area. Installed black iron piping with multiple red-handled shut-off valves, connected copper supply lines, and integrated flexible discharge hose into existing plumbing infrastructure. All connections tested and system operational upon completion.
Completed installation of water treatment system in basement utility area. Installed black iron piping with multiple red-handled shut-off valves, connected copper supply lines, and integrated flexible discharge hose into existing plumbing infrastructure. All connections tested and system operational upon completion.
Dan A.
Dan A. Checked in
Completed installation of water treatment system in basement utility area. Installed black iron piping with multiple red-handled shut-off valves, connected copper supply lines, and integrated flexible discharge hose into existing plumbing infrastructure. All connections tested and system operational upon completion.
Austin, MN 55912
Austin, MN - Responded to no cooling complaint on air conditioning system. Diagnosed low voltage short circuit and failed contactor. Replaced defective contactor to restore proper system operation.
Braden P.
Braden P. Checked in
Responded to no cooling complaint on air conditioning system. Diagnosed low voltage short circuit and failed contactor. Replaced defective contactor to restore proper system operation.
Austin, MN 55912
Schedule Service Online
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 507-282-4328 .

By pressing Submit I agree to receive phone, email, or text messages from K&S Heating, Air Conditioning, Plumbing & Electrical to the provided mobile number and also agree to the K&S Heating, Air Conditioning, Plumbing & Electrical terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next